FIRE PANELS

Addressable Fire Panel 2 Loops
Fire Alarm Siren
Our Reference:
KFP-AF2-21
Technology Addressable, intelligent panel
Loops 2 loops class A or B, extendible up to 4
  • 500 addresses per loop (250 detectors / 250 modules, call points)
  • Compatible with the most devices of the KSA701/2 panel
  • Allows to programm delay for sounders (horns/sirens)
  • Allows to programm horns drive delay
  • 83 x 44 mm LCD display
  • 2 monitored horns outputs
  • Timed driving
  • 99 events memory
  • Max. length of the loop wire: 2 km
  • Max. distance between 2 fire panels: 1.2 km
  • Aux. output 24 V
  • Voltage: 110 or 230 Vac (+10% -15%)
  • Batteries voltage: 24 Vdc (2 x 12 V, 7 A)
  • Operation temperature: -5 C to 40 C
  • Approvals: CE
Dimensions (W x H x D) ~450 x 580 x 173 mm
Weight ~7.4 kg (without the batteries

Analog Addressable Fire Panel KSA701/2
Fire Alarm Siren
Our Reference:
KSA701/2
Technology Analogue addressable fire detection panel
Loops 2 loops class A
  • 250 addresses per loop
  • Allows to programm delay for sounders (horns/sirens)
  • Driving by an easily programable alghorithm which allows boolean functions, coincidence within zones, adjustable thresholds for each sensor
  • LCD display
  • 2 monitored horns outputs
  • Timed driving
  • Output for printers(Parallel)
  • Demo Software Installed
  • Aux. output 24 V
  • Voltage: 110 or 230 Vac (+10% -15%)
  • Batteries voltage: 24 Vdc (2 x 12 V, 7 A)
  • Current Consuption: 175 mA (Quiest) e 241 mA (Alarm)
  • Operation temperature: -5 C to 40 C
Dimensions (W x H x D) ~420 x 335 x 110 mm
Weight ~6.2 kg (without the batteries

Conventional Fire Panel NK716
Fire Alarm Siren
Our Reference:
NK716
Technology Conventional Fire Panel
Loops 0 Loops
  • 16 zones(up to 20 detectors per zone)
  • 2 Monitored Sound Outputs
  • 2 User Access Levels
  • Alarm output with potential free relay
  • External Watchdog
  • Voltage: 110 or 230 Vac (+10% -15%)
  • Batteries voltage: 24 Vdc (2 x 12 V, 7 A)
  • Current Consuption: 175 mA (Quiest) e 241 mA (Alarm)
  • Operation temperature: -5 C to 40 C
Dimensions (W x H x D) ~420 x 335 x 110 mm
Weight ~6.2 kg (without the batteries